What to do if you get an alert of “The number of logs is up to the limit”

База знания
Ръководство за отстраняване на неизправности
07-23-2024
18430

This article applies to Omada SDN Controller v5.0 and above.

You may receive an alert of “The number of logs is up to the limit”. This article will explain why you get the alert and how to handle it.

1. the maximum number of logs.

The maximum number of logs for OC200 and OC300 is 11000 and 101000, respectively.

For Omada Software Controller, the maximum number of logs depends on the number of managed Omada devices.

If the number of managed Omada devices (let's say x) does not exceed 100, the maximum number of logs is 150 * 31 * x. If the number exceeds 100, the maximum number of logs is 150 * 31 * 100 + 30 * 31 * (x-100).

When the number of logs in your controller exceeds the upper limit, you will receive an alert of “The number of logs is up to the limit”.

2. What to do?

Omada SDN Controller will automatically delete the oldest 10% of logs. Therefore, you may not worry about that.

But if you get such alerts frequently, there are probably a lot of client roaming events, which generate many logs. You can go to Log – Notifications, to adjust the notification settings. For example, you can uncheck “Log full” notification in System, or “Client Roaming (Wireless)” notification in Client, or other frequent log types.

Моля, оценете този документ

Свързани документи

How to eliminate Port Blocked Alert

Ръководство за конфигуриране
10-28-2024
18085

How to eliminate WAN IP address Obtaining Failed alert

Ръководство за конфигуриране
Онлайн
10-28-2024
16759

How to get a backup file on Omada Controller v6 and above

Ръководство за отстраняване на неизправности
04-08-2026
4631

How to configure the Session Limit and Bandwidth Control to control traffic on Omada Gateways

Ръководство за конфигуриране
03-07-2026
5752

How to configure Multicast/Broadcast Rate Limit

Ръководство за конфигуриране
12-10-2025
16057